Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(7): e28298, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38560159

RESUMO

The aim was to evaluate the concurrent validity and reliability of the Resistance Intensity Scale for Exercise [RISE], which uses verbal descriptors, to quantify the intensity in velocity-based training with elastic bands. Eighteen trained volunteers performed parallel squats at maximum speed at 40%, 55%, 70%, and 85%1RM in four sessions, two for familiarization and two for reliability. Each set was stopped at a 10% intra-set velocity loss. Participants reported the perceived effort (easy-low-moderate-hard-maximal) at the first and last repetition. The concurrent validation was conducted with external load (i.e., mean propulsive velocity, weight, repetitions, and maximum power) and internal load parameters (i.e., heart rate). Participants' relative strength was calculated to assess its influence on the dependent variable. Acceptable concurrent validity and reliability (ICC>0.77, CV<21%) were observed, with the perceived effort being appropriate to differentiate between intensities and not being influenced by the participants' relative strength (p = 0.88). A categorical linear regression showed significant (p < 0.001) associations between the RISE scores and the weight, repetitions, and mean propulsive velocity (r = 0.43-0.63). The findings certify the usefulness of the perceived exertion for quantifying the intensity during velocity-based training with elastic bands. The perceived exertion of the first and last repetition favors a proper dosage of the training load.

2.
PeerJ ; 12: e17008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464757

RESUMO

This study aimed to compare the mechanical (lifting velocity and maximum number of repetitions), physiological (muscular activation, lactate, heart rate, and blood pressure), and psychological (rating of perceived exertion) responses to upper-body pushing exercises performed wearing a sports elastomeric garment or a placebo garment. Nineteen physically active young adults randomly completed two training sessions that differed only in the sports garment used (elastomeric technology or placebo). In each session, subjects performed one set of seated shoulder presses and another set of push-ups until muscular failure. The dependent variables were measured immediately after finishing the set of each exercise. Compared to the placebo garment, the elastomeric garment allowed participants to obtain greater muscular activation in the pectoralis major (push-ups: p = 0.04, d = 0.49; seated shoulder press: p < 0.01, d = 0.64), triceps brachialis (push-ups, p < 0.01, d = 0.77; seated shoulder press: p < 0.01, d = 0.65), and anterior deltoid (push-ups: p < 0.01, d = 0.72; seated shoulder press: p < 0.01, d = 0.83) muscles. Similarly, participants performed more repetitions (push-ups: p < 0.01; d = 0.94; seated shoulder press: p = 0.03, d = 0.23), with higher movement velocity (all p ≤ 0.04, all d ≥ 0.47), and lower perceived exertion in the first repetition (push-ups: p < 0.01, d = 0.61; seated shoulder press: p = 0.05; d = 0.76) wearing the elastomeric garment compared to placebo. There were no between-garment differences in most cardiovascular variables (all p ≥ 0.10). Higher diastolic blood pressure was only found after the seated shoulder press wearing the elastomeric garment compared to the placebo (p = 0.04; d = 0.49). Finally, significantly lower blood lactate levels were achieved in the push-ups performed wearing the elastomeric garment (p < 0.01; d = 0.91), but no significant differences were observed in the seated shoulder press (p = 0.08). Overall, the findings of this study suggest that elastomeric technology integrated into a sports garment provides an ergogenic effect on mechanical, physiological, and psychological variables during the execution of pushing upper-limb resistance exercises.


Assuntos
Treinamento de Força , Adulto Jovem , Humanos , Ombro/fisiologia , Levantamento de Peso/fisiologia , Lactatos , Vestuário
3.
Healthcare (Basel) ; 12(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38255091

RESUMO

The bulk of research on microfiltered seawater (SW) is based on its short-term effects. However, the long-term physiological adaptations to combining SW and resistance training (RT) are unknown. This study aimed to analyse the impact of an RT program using elastic bands combined with SW intake on hepatic biomarkers, inflammation, oxidative stress, and blood pressure in post-menopausal women. Ninety-three women voluntarily participated (age: 70 ± 6.26 years; body mass index: 22.05 ± 3.20 kg/m2; Up-and-Go Test: 6.66 ± 1.01 s). RT consisted of six exercises (32 weeks, 2 days/week). Nonsignificant differences were reported for hepatic biomarkers except for a reduction in glutamic-pyruvic transaminase (GPT) in both RT groups (RT + SW: p = 0.003, ES = 0.51; RT + Placebo: p = 0.012, ES = 0.36). Concerning oxidative stress, vitamin D increased significantly in RT + SW (p = 0.008, ES = 0.25). Regarding inflammation, interleukin 6 significantly decreased (p = 0.003, ES = 0.69) in RT + SW. Finally, systolic blood pressure significantly decreased in both RT groups (RT + placebo: p < 0.001, ES = 0.79; RT + SW: p < 0.001, ES = 0.71) as did diastolic blood pressure in both SW groups (RT + SW: p = 0.002, ES = 0.51; CON + SW: p = 0.028, ES = 0.50). Therefore, RT + SW or SW alone are safe strategies in the long term with no influences on hepatic and oxidative stress biomarkers. Additionally, SW in combination with RT positively influences vitamin D levels, inflammation, and blood pressure in older women.

4.
J Strength Cond Res ; 38(1): 206-219, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38085630

RESUMO

ABSTRACT: Babiloni-Lopez, C, Fritz, N, Ramirez-Campillo, R, and Colado, JC. Water-based exercise in patients with nonspecific chronic low-back pain: a systematic review with meta-analysis. J Strength Cond Res 38(1): 206-219, 2024-This study aimed to systematically review and synthesize evidence (i.e., active [land-based training] and nonactive controls [e.g., receiving usual care]) regarding the effects of water-based training on patients with nonspecific chronic low-back pain (NSCLBP). Web of Science (WOS), PubMed (MEDLINE), EMBASE, EBSCO (SPORTDiscus; CINAHL), and PEDro were searched, with no date restrictions, until October 2021. The included studies satisfied the following criteria: (a) NSCLBP (≥12 weeks) patients, (b) water-based intervention, (c) control group (land-based trained; nonactive group), and (d) outcomes related to pain, disability, quality of life, or flexibility. The main outcome analyzed in the meta-analysis was pain intensity. Secondary outcomes included disability, body mass index, and flexibility. The random-effects model was used, and effect size (ES) values are presented with 95% confidence intervals (CIs). The impact of heterogeneity was assessed (I2 statistic), with values of <25%, 25-75%, and >75% representing low, moderate, and high levels, respectively. Alpha was set at p < 0.05. In conclusion, 15 studies (n = 524) were meta-analyzed. After intervention, pain intensity was reduced compared with nonactive controls (ES = -3.61; p < 0.001) and a similar reduction was noted when compared with land-based trained group (ES = -0.14; p = 0.359). Greater decrease in disability (ES = 2.15; p < 0.001) and greater increase in sit-and-reach (i.e., flexibility; ES = -2.44; p < 0.001) were noted after intervention compared with the nonactive group. In conclusion, water-based exercise therapy reduces pain intensity, disability, and increases flexibility in NSCLBP compared with nonactive subjects and was equally effective compared with land-based exercise to reduce pain. Favorable effects may be expected at ≤8 weeks. However, due to several methodological issues (e.g., high heterogeneity), for the improvement of most outcomes, we are unable to provide other than a weak recommendation in favor of intervention compared with control treatment.


Assuntos
Dor Crônica , Qualidade de Vida , Humanos , Água , Exercício Físico , Terapia por Exercício , Dor nas Costas/terapia , Dor Crônica/terapia
5.
Motor Control ; 27(4): 830-843, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37527822

RESUMO

Several devices (e.g., linear transducers) have been used for predicting resistance training intensity. However, subjective scales, such as rating of perceived exertion (RPE), are proposed as reliable and easier-to-use tools for monitoring intensity during resistance training. Accordingly, different perceptive scales have been presented in previous research for monitoring intensity during resistance training with elastic bands. The aim was to assess the accuracy and reliability of RPE for quantifying the potential maximal repetitions that could be performed at a given RPE (from 2 to 8 of 10) obtained in the first repetition. For this purpose, 13 recreationally active participants (age: 26.33 [6.52] years, body mass index: 24.97 [5.08] kg/m2) were involved in two familiarization and two experimental sessions. In each session, participants randomly performed one set at each intensity of the first repetition from 2/10 to 8/10 until volitional failure in three different exercises (fly, military press, and push-press). An individual grip width of the elastic band was chosen in each set. The number of repetitions and heart rate were assessed. Significance level was set at p < .05. Repetitions decreased when intensity increased (p < .01) and heart rate was higher in the global exercise (i.e., push-press; p < .05), but nonsignificant differences between intensities were reported. The level of experience influenced the number of repetitions performed (p < .05). Intersession reliability was set from good to excellent (range: 0.64-0.91). Therefore, the RPE of the first repetition is a relevant and reliable parameter related to the total number of repetitions performed for each RPE value in trained participants enrolled in elastic bands resistance training.

6.
Artigo em Inglês | MEDLINE | ID: mdl-36981609

RESUMO

The aim was to explore the effects of a 32-week resistance training (RT) intervention with elastic bands with or without microfiltered seawater (SW) supplementation on isokinetic strength, bone mineral density (BMD), body composition, and subjective quality of life in postmenopausal women. Ninety-three untrained women (age: 70.00 ± 6.26 years; body mass index: 22.05 ± 3.20 kg/m2; body fat: 37.77 ± 6.38%; 6.66 ± 1.01 s up-and-go test) voluntarily participated in this randomized, double-blinded, controlled trial. Participants were allocated into four groups (RT+SW, RT+PLA, CON+SW, and CON+PLA). The RT intervention (twice weekly) consisted of different exercises for the whole body performed at submaximal intensities with elastic bands. Both control groups were not involved in any exercise program. A two-way mixed analysis of variance of repeated measures revealed significant improvements in almost all the variables in both intervention groups (p < 0.05). However, significant differences with controls were encountered in isokinetic strength, body fat percentage, and bodily pain. Although the group with SW supplementation obtained greater effect sizes, non-significant differences between both RT groups were observed. In conclusion, the determinant factor of the adaptations seems to be RT rather than SW.


Assuntos
Treinamento de Força , Humanos , Feminino , Idoso , Pessoa de Meia-Idade , Qualidade de Vida , Densidade Óssea , Suplementos Nutricionais , Composição Corporal , Poliésteres , Força Muscular , Músculo Esquelético
7.
Artigo em Inglês | MEDLINE | ID: mdl-36554498

RESUMO

The objective was to compare the mean propulsive velocity (MPV), maximum power (PMAX), heart rate, and rate of perceived exertion (RPE) during the parallel squat using elastic bands (EB) or weight plates (WP) to load the bar. The effect of relative strength on the dependent variables was analysed. Additionally, the potential of the RPE to predict external load parameters was assessed. Eighteen trained volunteers squatted at 40%, 55%, 70%, and 85% of their one-repetition maximum with EB and WP (a total of eight sets) in random order. Dependent variables were measured at the first and last repetition (i.e., 10% velocity loss). Two identical sessions were conducted to assess the reliability of measurements. Compared to WP, EB allowed a significantly greater number of repetitions, MPV, and PMAX, and significantly lower RPE. The RPE of the first repetition was a significant predictor of the external load of the set. The RPE showed good repeatability and was not influenced by the relative strength of athletes. In conclusion, compared to WP, the use of EB allows for greater external load with reduced internal load responses in a wide spectrum of load-based intensities. The potential implications of these novel findings are discussed in the manuscript.


Assuntos
Treinamento de Força , Humanos , Reprodutibilidade dos Testes , Percepção/fisiologia , Esforço Físico/fisiologia , Atletas , Força Muscular/fisiologia , Músculo Esquelético/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...